Humidity indicators
Humidity indicators in combination with the drying agents serve as a
guide to the climate and moisture level inside the packaging. Humidity
indicators consist of a special absorbent paper. Several areas of the
paper are printed with cobalt (II) chloride solution varying in concentration.
The numbers inside the moisture sensitive spots indicate the relative
humidity with a visible colour change from blue to pink. A drop in humidity
is shown through the reverse process of the colour change.
APPLICATION
The humidity indicators are placed either inside the barrier foil or form
a part of the vision panels or viewing plugs. Properly packaged exported
goods with sufficient desiccants experience a 20% RH drop at normal temperature
within a very short period of time. The colour of the humidity indicator
used should therefore be blue in the 30% spot. If this should not be the
case after 2 to 3 days have passed, the packaging ought to be inspected
for any leaks or tears, too low amounts of drying agents or moist packaged
goods. The colour reaction of the humidity indicator card, however, can
be delayed through low temperature levels during winter time, a lack of
air circulation between humidity indicator and drying agent or foils not
suitable for the purpose.
ACCURACY
The humidity indicator cards are small-sized, easy to handle and inexpensive.
When it comes to precision they should not be directly compared with expensive
and sophisticated electronic measuring equipment. An inspection temperature
of 20°C (+-2°C) allows for a tolerance level of + -5% RH. The humidity
indicators thus comply with the military technical specifications TL 6685-0003
version 4 (September 1996). Please note that the colour change in regions
with extreme climatic conditions maybe delayed or decreased, depending
on whether the temperature is above or below 20°C. The deviation levels
are approx. 2.5% RH for each 5°C above, resp. below 20°C.
|